What we found when testing several competitor's models, is that the majority of detox was not coming from the patient into the water, but that the array was breaking down it's metals into the water.  Despite the many misleading claims and staggering mis-information.....a definite breakdown of metals occur directly into the water container.  Unfortunately, the key test is this......start a unit in a bucket WITHOUT a person in the bucket, the same metal residue appears.  Start a unit in a bucket WITH a person, the same metal residue appears.  There may actually be more metal residue created with a body in the bucket because the energy of the person influences the electrolysis.  As the rings, clips, copper, and metals of the water array breaks down and pocks, there is even more residue created with subsequent footbaths. 

Supporting our research and test results is a TV news exposé on claims made by a competitors footbath unit.  Click on the following link - You will be sent to KVBC.com Channel 3 in Las Vegas, Nevada

Healing waters or medical hoax?

 

We tested patients before and after to find if elements like arsenic, beryllium, cadmium , nickel, aluminum, tin, tungsten, and lead existed in their system prior to footbaths - these elements exist in footbath water with a body in the water or without a body in the water - but these elements don't necessarily exist in the body of patients.  We can show that detox occurs with compounds like Mercury, but over time - months of treatments and with complementary food choices and complementary treatment choices. 

When you ask for or view competitor's "test results of water" you will see a large list of metals, alloys and metal components - it is the same test results we obtained when testing competitors models.  It does not prove in any way that those components are released from the body.  Before and after testing of hair, urine, fecal matter, blood, chelation, biofeedback, kinesiology, etc... will show levels of detoxification.  When tested, the sludge does not produce yeast, cancer cells, leukemia or other health ailments and symptoms. 

 

Testing Conducted by Doctor’s Data Lab, St. Charles Illinois

Element Water ppm  "vendor x" w/person ppm Difference % change
           
Beryllium 0.000 0.000 0.000 0.00%  
Aluminum 0.245 1.160 0.915 373% 0.006
Nickel 0.002 39.100 39.098 1954900% 0.1
Arsenic 0.000 0.016 0.016 2% 0.01
Cadmium 0.000 0.016 0.016 2%  
Tin 0.000 0.055 0.055 6%  
Antimony 0.000 0.005 0.005 1%  
Tungsten 0.000 0.305 0.305 31%  
Mercury 0.000 0.011 0.011 1% 0.002
Lead 0.001 0.008 0.007 700% 0.015
Bismuth 0.000 0.001 0.001 0%  
Thorium 0.000 0.002 0.002 0%  
Copper 0.233 11.040 10.807 4638% 0.017
           
total 0.481 51.719 51.2381960652. 77% 0.150
           
Wellborn Test  "vendor x" No person      
           
Beryllium 0.000 0.000 0. 000 0.000 0.000
Aluminum 0.245 1.160 0.350 0.115 0.182
Nickel 0.002 39.100 16.700 0.012 7.380
Arsenic 0.000 0.016 0.009 0.000 0.004
Cadmium 0.000 0.016 0.010 0.000 0.005
Tin 0.000 0.055 0.017 0.000 0.008
Antimony 0.000 0.005 0.003 0.000 0.000
Tungsten 0.000 0.305 0.074 0.000 0.058
Mercury 0.000 0.011 0.000 0.000 0.000
Lead 0.001 0.008 0.001 0.000 0.000
Bismuth 0.000 0.001 0.000 0.000 0.000
Thorium 0.000 0.002 0.000 0.000 0.000
Copper 0.233 11.040 6.790 0.065 1.470
           
total 0.481 51.719 23.954 0.192 9.107
Element "vendor y" ppm no body in water "vendor y"  ppm w/body in water      
           
Arsenic 4.3 4.2      
Barium 52 54      
Cadmium 2.1 2.0      
Chromium 12000 12000      
Copper 1700 2200      
Mercury 1.5 1.5      
Nickel 6200 5800      
Aluminum 71 76      
Iron 39000 39000      
Zinc 598 1150      
Manganese 780 730      